OS GSO IEC 60793-1-44:2024
IEC 60793-1-44:2023
Omani Standard
Current Edition
·
Approved on
14 October 2024
Optical fibres - Part 1-44: Measurement methods and test procedures - Cut-off wavelength
OS GSO IEC 60793-1-44:2024 Files
No files for this standard are available in the store currently.
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
OS GSO IEC 60793-1-44:2024 Scope
IEC 60793-1-44:2023 establishes uniform requirements for measuring the cut-off wavelength of single-mode optical fibre, thereby assisting in the inspection of fibres and cables for commercial purposes. This document gives methods for measuring the cut-off wavelength for uncabled or cabled single mode telecom fibre. These procedures apply to all category B and C fibre types. There are three methods of deployment for measuring the cut-off wavelength:
- method A: cable cut-off using uncabled fibre 22 m long sample, lcc;
- method B: cable cut-off using cabled fibre 22 m long sample, lcc;
- method C: fibre cut-off using uncabled fibre 2 m long sample, lc.
All methods require a reference measurement. There are two reference-scan techniques, either or both of which can be used with all methods:
- bend-reference technique;
- multimode-reference technique using category A1(OM1-OM5) multimode fibre.
This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) used the diameter of the fibre loops to describe deployment;
b) added Annex D related to cut-off curve artifacts;
c) reorganized information and added more figures to clarify concepts.
- method A: cable cut-off using uncabled fibre 22 m long sample, lcc;
- method B: cable cut-off using cabled fibre 22 m long sample, lcc;
- method C: fibre cut-off using uncabled fibre 2 m long sample, lc.
All methods require a reference measurement. There are two reference-scan techniques, either or both of which can be used with all methods:
- bend-reference technique;
- multimode-reference technique using category A1(OM1-OM5) multimode fibre.
This third edition cancels and replaces the second edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) used the diameter of the fibre loops to describe deployment;
b) added Annex D related to cut-off curve artifacts;
c) reorganized information and added more figures to clarify concepts.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO IEC 61010-2-033:2025
IEC 61010-2-033:2023
Gulf Standard
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
GSO IEC 60335-2-124:2025
IEC 60335-2-124:2024
Gulf Standard
Household and similar electrical appliances - Safety - Part 2-124: Particular requirements for commercial dry ice blasting machines
GSO IEC 61347-2-11:2025
IEC 61347-2-11:2024
Gulf Standard
Controlgear for electric light sources - Safety - Part 2-11: Particular requirements - Miscellaneous electronic circuits used with luminaires
GSO IEC 60287-1-3:2025
IEC 60287-1-3:2023
Gulf Standard
Electric cables - Calculation of the current rating - Part 1-3: Current rating equations (100 % load factor) and calculation of losses - Current sharing between parallel single-core cables and calculation of circulating current losses